Unidrive M751 M751-03400160A10100AB101 Variable Frequency Drive
CTRL TECHNIQUES M751 Fr.03 RUN 0.0Hz 16.0A 0kW 7.5 kW 400V 16.0A
M751-03400160A10100AB1
Representative image
7.5 kW
Power
400V
Supply
16.0A
Output current
Fr.03
Frame

M751-03400160A10100AB101
7.5 kW 400V Compact VFD

7.5 kW / 10 HP 400V Supply 16.0A Output Frame 03 CompactIntegrated EMC Filter
ℹ️
M751 — M750 with Integrated EMC Filter
The M751 is electrically and mechanically identical to the M750 but includes an integrated C2/C3 EMC filter. This eliminates a separate external filter, saving space and reducing installation cost in EMC-sensitive machine environments.

Quick answer: The M751-03400160A10100AB101 is a Control Techniques Unidrive M751 rated at 7.5 kW (10 HP) for 380–480V ±10%, 3-phase supply with 16.0A output. Compact High-Performance Drive with Integrated EMC Filter. Frame 03, IP20.

Technical Specifications

Electrical
Model NumberM751-03400160A10100AB101
SeriesUnidrive M751
Power Rating7.5 kW (10 HP)
Output Current16.0 A
OverloadNormal Duty (110% / 60 s)
Supply Voltage380–480V ±10%, 3-phase
Output Frequency0–3,200 Hz
Mechanical
Frame SizeFrame 03
Dimensions (H×W×D)H: 265 mm × W: 90 mm × D: 195 mm
ProtectionIP20 / UL Type 1
Ambient Temperature-10°C to +50°C
Safety & Communications
Safety FunctionsSTO, SBC — PL-d / SIL 2
CommunicationsProfinet + EtherNet/IP (AB101); Profibus, CANopen optional

Quick Quote

Formal RFQ Form
24-hour quote response
FOB / CIF / DDP available
English / Russian / Chinese

Applications

  • Food and pharma machinery (EMC-sensitive environment)
  • Medical device manufacturing axes
  • Compact servo drives in CE-marked machines
  • Lab automation equipment
  • Clean-room compatible packaging drives

Common Fault Codes & Remedies

Applicable to CT M751 series. Isolate supply before investigating.

Fault Name Cause & Remedy
Err 3OvercurrentCheck for output short circuit or undersized drive. Increase acceleration ramp (Pr 0.03).
Err 7OvervoltageRegenerative load without braking resistor, or deceleration too fast. Add braking resistor or extend decel ramp.
Err 4UndervoltageSupply voltage below threshold. Check incoming supply and verify stability under load.
Err 15Drive overtemperatureHeatsink overheated. Check ambient temp (max 40°C), clean filter, verify fan operation.
Err 23Motor overtemperaturePTC thermistor tripped or I²t limit exceeded. Check for mechanical jam, verify motor cooling.
Err 46STO activeSafe Torque Off input opened. Check safety circuit wiring to STO terminals.
Err 27Supply lossInput phase loss. Check supply connections and incoming fuses/breaker.
Err 1Phase loss (output)Open circuit on output — motor cable disconnected. Check motor connection and cable.
Err 29Brake IGBT faultBraking IGBT over-temperature. Check braking resistor connection and resistance value.