Unidrive M702 M702-09402000A10100AB100 Variable Frequency Drive
110 kW
Power
400V
Supply
200.0A
Output current
Fr.09
Frame size

M702-09402000A10100AB100
110 kW 400V Variable Frequency Drive

110 kW / 148 HP 400V Supply 200.0A Output Frame 09 Integrated EMC Filter
ℹ️
M702 vs M700 — Integrated EMC Filter
The M702 is electrically and mechanically identical to the M700 but includes an integrated C2/C3 EMC filter as standard. This removes the need for a separate external filter, saving panel space and reducing BOM cost. All motion performance, safety functions, and fieldbus options are identical to the M700.

Quick answer: The M702-09402000A10100AB100 is a Control Techniques Unidrive M702 rated at 110 kW (148 HP) for 380–480V ±10%, 3-phase supply with 200.0A output. High-performance AC/Servo Drive with Integrated EMC Filter. Frame 09, IP20.

Technical Specifications

Electrical
Model NumberM702-09402000A10100AB100
SeriesUnidrive M702
Power Rating110 kW (148 HP)
Output Current200.0 A
Overload CapabilityNormal Duty (110% / 60 s)
Supply Voltage380–480V ±10%, 3-phase
Output Frequency0–3,200 Hz (M702) / 0–1,000 Hz (C200/C300)
Mechanical
Frame SizeFrame 09
Dimensions (H×W×D)H: 1200 mm × W: 375 mm × D: 380 mm
Protection RatingIP20 / UL Type 1
Ambient Temperature-10°C to +50°C (derate above 40°C)
Storage Temperature-40°C to +60°C
Safety & Communications
Safety FunctionsSTO, SBC, SS1, SS2, SLS — PL-e / SIL 3 (same as M700)
CommunicationsProfinet IRT + EtherNet/IP standard (AB100); optional EtherCAT, PROFIBUS

Quick Quote

Formal RFQ Form
24-hour quote response
FOB / CIF / DDP available
English / Russian / Chinese

Applications

  • 4-way shuttle AS/RS travel axes (same as M700)
  • Sensitive installations requiring low EMC emissions
  • Food/pharma where external filter is impractical
  • AMR/AGV drive control with high dynamic requirement
  • Cold chain ASRS (IP55 panel + heater required)

Common Fault Codes & Remedies

Applicable to Control Techniques M702 series. Always isolate supply before investigating faults.

Fault Name Cause & Remedy
Err 3OvercurrentOutput short circuit or undersized drive. Check motor wiring, increase acceleration ramp (Pr 0.03), verify drive current rating ≥ motor FLC.
Err 7OvervoltageRegenerative load without braking resistor, or deceleration too fast. Add braking resistor, increase deceleration time (Pr 0.04).
Err 4UndervoltageSupply voltage below threshold. Check incoming supply, verify supply stability under load.
Err 15Drive overtemperatureHeatsink overheated. Check ambient temp (max 40°C), clean filters, verify fan operation, reduce switching frequency.
Err 23Motor overtemperaturePTC thermistor tripped or motor I²t limit exceeded. Check for mechanical jam, verify motor cooling, check PTC wiring.
Err 27Supply lossOne or more input phases lost. Check supply connections, verify 3-phase symmetry, check incoming fuses.
Err 46STO activeSafe Torque Off input opened. Check safety circuit wiring to STO terminals, verify safety relay output.
Err 1Phase loss (output)Open circuit on output — motor cable disconnected. Check motor connection and cable continuity.
Err 12Fieldbus timeoutProfinet / EtherNet/IP communication lost. Check Ethernet cable, verify PLC watchdog settings, check IP configuration.
Err 29Brake IGBT faultBraking IGBT over-temperature or short circuit. Check braking resistor connection and resistance value.

Related M702 Models

View All M702 Models →

Frequently Asked Questions

Ready to order M702-09402000A10100AB100?

24-hour competitive quote with lead time. DDP delivery worldwide.