Unidrive M701 M701-03400025A Variable Frequency Drive
0.75 kW
Power rating
400V
Supply voltage
2.5A
Output current
Fr.03
Frame size

M701-03400025A — 0.75 kW 400V VFD

0.75 kW / 1 HP 400V Supply 2.5A Output Frame 03 Profinet + EtherNet/IP STO PL-e / SIL 3 Advanced Motion Controller Safety PLC Onboard
ℹ️
M701 vs M700 — What's different?
The M701 is mechanically and electrically identical to the M700 but adds an onboard Advanced Safety PLC with full TÜV-certified safety functions: STO, SBC, SS1, SS2, SLS, SOS, SSM, SDI, and SLI — all to Performance Level e (PL-e / SIL 3). Specify M701 when your machine requires independently certified multi-axis safe speed/position functions without an external safety relay module.

Quick answer: The M701-03400025A is a Control Techniques Unidrive M701 variable frequency drive rated at 0.75 kW (1 HP) for 380–480 V ±10%, 3-phase supply. It delivers 2.5A output current, Frame 03 (IP20 / UL Type 1), with onboard Profinet/EtherNet/IP and STO safety to Performance Level e. Ideal for shuttle AS/RS travel axes, conveyors, and servo-class positioning applications.

Technical Specifications

Electrical
Model NumberM701-03400025A
SeriesUnidrive M701
Power Rating0.75 kW (1 HP)
Output Current (rated)2.5 A
Overload CapabilityNormal Duty (110% / 60 s)
Supply Voltage380–480 V ±10%, 3-phase
Output Frequency0–3,200 Hz
PWM Switching Frequency2–16 kHz (selectable)
Mechanical
Frame SizeFrame 03
Dimensions (H × W × D)H: 275 mm × W: 70 mm × D: 188 mm
Protection RatingIP20 / UL Type 1
Ambient Temperature-10°C to +50°C (derate above 40°C)
Storage Temperature-40°C to +60°C
AltitudeUp to 3,000 m (derate above 1,000 m)
Communications & Control
Onboard FieldbusProfinet IRT + EtherNet/IP (AB100 variant)
Optional Fieldbus (SI slots)EtherCAT, PROFIBUS-DP, DeviceNet, Modbus TCP
Motion ControllerAdvanced Motion Controller, 250 µs cycle, RTMoE (IEEE 1588 V2)
Onboard PLCYes — IEC 61131-3 compatible, 1.5-axis
Safety
Standard Safety FunctionsSTO, SBC, SS1, SS2, SLS (PL-e / SIL 3)
Extended Safety (M701)+ SOS, SSM, SDI, SLI — TÜV certified Advanced Safety PLC onboard
Safety StandardIEC 61800-5-2, EN 13849-1 PL-e, IEC 62061 SIL 3
STO Response Time< 10 ms

Quick Quote

Formal RFQ Form
24-hour quote response
FOB / CIF / DDP available
Emergency stock available
English / Russian / Chinese

Recommended Applications

  • 4-way shuttle AS/RS travel axis (primary recommendation)
  • Stack crane hoist & travel axes
  • AMR drive motors (high dynamic response)
  • Cold chain ASRS (>= IP55 panel + heater required)
  • High-performance conveyor with position tracking

Common Fault Codes & Remedies

Applicable to all Unidrive M700 and M701 series drives. Always isolate mains supply before investigating wiring faults.

Fault Code Fault Name Cause & Remedy
Err 3 Overcurrent Output short circuit, undersized drive for motor, acceleration ramp too fast. Check wiring, increase accel time (Pr 0.03), verify drive current rating ≥ motor FLC.
Err 7 Overvoltage Regenerative load without braking resistor, deceleration too fast. Add external braking resistor (> 75kW frames), increase decel time (Pr 0.04), check supply voltage.
Err 4 Undervoltage Supply voltage below threshold: <175V (200V drive), <330V (400V drive). Check incoming supply, check DC bus fuse, verify supply stability under load.
Err 15 Drive overtemperature Heatsink > 100°C. Check ambient temperature (max 40°C), clean air filters, verify fan operation, reduce switching frequency (Pr 5.18).
Err 23 Motor overtemperature PTC thermistor tripped or motor I²t exceeded. Check for mechanical jam, verify PTC wiring (terminals TH, 0V), check motor cooling.
Err 27 Supply loss One or more input phases lost for >100ms. Check supply connections, check incoming fuses, verify 3-phase symmetry.
Err 46 STO active Safe Torque Off input opened — E-stop or safety relay de-energised. Check safety circuit wiring to STO terminals, check safety relay output.
Err 1 Phase loss (output) Open circuit on output — motor cable disconnected or phase-to-phase failure. Check motor connection, cable continuity, verify motor resistance.
Err 12 Fieldbus timeout Profinet / EtherNet/IP communication lost. Check Ethernet cable, verify PLC watchdog settings (Pr 10.40), check IP address configuration.
Err 29 Brake IGBT fault Internal braking IGBT over-temperature or short circuit. Check braking resistor connection, verify resistor value is within specification.

Cross-Reference — Equivalent Drives

Comparable drives from other brands at the same power rating (0.75 kW, 400V). Note: functional differences apply — always verify specifications before substitution.

Brand Model Number Notes
Control Techniques M701-03400025A This model — fastest dynamic response, STO PL-e, RTMoE synchronisation
ABB ACS580-01-02A7-4 0.75 kW, 400V — Direct Torque Control, preferred for hoist axes
Siemens SINAMICS G120 6SL3210-1KE11-8UF1 0.75 kW, 400V — SINAMICS G120, tight TIA Portal integration
Lenze 8400 HighLine 0.75 kW 0.75 kW — EtherCAT, compact DIN-rail mount for smaller frames

Related M701 Models

View All M701 Models →

Frequently Asked Questions — M701-03400025A

Ready to order M701-03400025A?

Submit your RFQ and receive a competitive price with lead time within 24 hours. FOB, CIF, and DDP delivery worldwide.